GuReater®CoCr Stent Sirolimus-eluting Coronary Stent System

Product Benefits

gureater-cocr-stent-sirolimus-eluting-coronary-stent-system-2.jpg

GuReater®

GuReater® CoCr Stent Sirolimus-eluting Coronary Stent System Details

Product Description

GuReater® is a CoCr drug-eluting stent covered with Sirolimus. Its 75 μm CoCr strut provides super flexibility and crossability to ensure great compliance after implantation.

Product Features

  • CoCr stent has great radiopacity and biocompatibility.
  • 75μm ultrathin strut guarantees the excellent flexibility of the stent during delivery and helps with better endothelialization.
  • Low recoil ratio of 3.4% for CoCr stent ensures better stent apposition to reduce the risk of thrombosis.
  • PLGA biodegradable polymer coating provides precise drug-releasing control and a scientific degradation period.
  • 75 μm ultrathin strut thickness and unique strut structure guarantee the excellent compliance of the stent during delivery.
  • CoCr stent has great radiopacity, and biocompatibility, and provides an excellent balance between radial strength and flexibility.
  • MRI compatible

GuReater®

Clinical Evidence

gureater-cocr-stent-sirolimus-eluting-coronary-stent-system-728.jpg

Large-scale Quality Tracking Research

  • 22 hospitals, 2,022 subjects
  • 12 months follow-up of 1699 cases, the main follow-up was the occurrence of adverse events
  • 50 cases had adverse events (2.94%), 2 cases died (0.12%), all of them were non-cardiac deaths, 4 cases had non-target blood vessel revascularization (0.24%)

Confirms that the GuReater® Sirolimus-eluting Coronary Stent System is safe and effective in a wide range of patients and lesion comprehensive performance. GuReater is a product with high clinical application value.

Product Ranges

  • 2.25-4.5 mm
  • 8-36 mm multi stent lengths

Ordering Information

Stent Length (mm)Stent DiameterØ (mm)
2.252.52.753.03.54.04.5
8LPRPC2208//////
12LPRPC2212LPRPC2512LPRPC2712LPRPC3012LPRPC3512LPRPC4012LPRPC4512
15LPRPC2215LPRPC32515LPRPC2715LPRPC3015LPRPC3515LPRPC4015LPRPC4515
18LPRPC2218LPRPC2518LPRPC2718LPRPC3018LPRPC 3518LPRPC4018LPRPC4518
21LPRPC2221LPRPC2521LPRPC2721LPRPC3021LPRPC3521LPRPC4021LPRPC4521
24LPRPC2224LPRPC2524LPRPC2724LPRPC3024LPRPC3524LPRPC4024LPRPC4524
29LPRPC22296LPRPC2529LPRPC2729LPRPC3029LPRPC3529LPRPC4029LPRPC4529
33LPRPC2233//LPRPC30233LPRPC3533LPRPC4033LPRPC4533
36LPRPC2236//LPRPC3036LPRPC3536LPRPC4036LPRPC4536

Specifications

Technical Parameters
Stent MaterialL605 CoCr Alloy
Strut DesignOpen cell
Metal to Artery Ratio15%
Recoil3.40%
Strut Thickness75 μm
Crossing Profile0.035″(0.90mm)